Sumitomo F50 Compressor Manual New -

Whether you are executing a brand-new installation, performing a routine 30,000-hour system overhaul, or looking to download the official technical literature, this comprehensive manual guide outlines everything you need to know about setting up, monitoring, and servicing your new F-50 compressor configuration. Key Technical Specifications

The F50 is equipped with an advanced control system. A new manual explains the operation of the digital interface, allowing operators to monitor: Motor Amperage. Running Hours & Maintenance Reminders. Key Operating Procedures:

Are you working with the or air-cooled (FA-50) model? sumitomo f50 compressor manual new

The Sumitomo Freedom® Series F-50 helium compressor line features both water-cooled (F-50H, F-50L) and air-cooled variations (FA-50 models) to match facility infrastructure. The system acts as the direct upgrade to the legacy CSW-71D series, sharing the same capsule structure while providing an improved oil separation cycle. Low-Voltage Variant (e.g., F-50L / High-Voltage Variant (e.g., F-50H / Electrical Supply 3-Phase, 200 V at 50/60 Hz Electrical Supply 3-Phase, 380–415 V (50 Hz) / 460–480 V (60 Hz) Power Consumption 6.5–7.2 kW (50 Hz) / 7.5–8.3 kW (60 Hz) Power Consumption 6.5–7.2 kW (50 Hz) / 7.5–8.3 kW (60 Hz) Static Gas Pressure 1.60 – 1.65 MPa at 20 °C Static Gas Pressure 1.45 – 1.50 MPa at 20 °C (Varies by cold head) Operating Weight Approx. 120 kg (264 lbs) Operating Weight Approx. 120 kg (264 lbs) Dimensions (HxWxD) 591 x 450 x 585 mm Dimensions (HxWxD) 591 x 450 x 585 mm Cooling Requirements Water: 7–10 L/min (4–28 °C inlet) Cooling Requirements /min flow rate (for FA series) Maintenance Cycle 30,000 Hours Maintenance Cycle 30,000 Hours Unboxing & Pre-Installation Rules

Turn off the compressor motor via the control drive switch. Crucial Step: Wait approximately 15 minutes before shutting down the water chiller. This allows residual heat within the compressor capsule to disperse safely, avoiding thermal shock. Vital 30,000-Hour Maintenance & Care Running Hours & Maintenance Reminders

Keep the room temperature between 5°C and 35°C (41°F to 95°F). If the room gets hotter than 28°C (82°F), the cooling power will drop.

Before making tool connections, verify the supply pressure gauge. At a standard 20 °C environment, it must read between 1.45 MPa and 1.65 MPa depending on your paired cold head model. If the level is beneath factory minimums, you must refill it with 99.999% pure helium before startup. 2. Laying and Connecting Flex Lines The system acts as the direct upgrade to

3-phase, 200 V (50/60 Hz) for F-50L; 3-phase, 380–480 V for F-50H.

The provides essential technical protocols for installing, operating, and servicing the SHI Freedom® series mid-size cryogenic compressors . Engineered primarily for high-performance Magnetic Resonance Imaging (MRI) systems, these water-cooled and air-cooled units supply high-pressure, ultra-pure helium gas to operate Gifford-McMahon (GM) cryocoolers and pulse tube cold heads.

Check phase rotation; running the compressor backward can cause permanent damage to the scroll mechanism. Water Line Integration

Installing a requires precision to ensure long-term reliability. The manual outlines strict guidelines: